Demystifying DALI-2 Emergency Lighting: JINYI’s Complete Solution & Project Selection Guide
Release time:
2026-07-24
JINYI is proud to announce the launch of our fully compliant DALI-2 Smart Emergency Lighting Solution.
The evolution of smart buildings has fundamentally shifted how we approach life safety. As modern infrastructure becomes more complex, the demand for highly reliable, automated, and interconnected safety systems has skyrocketed. At the forefront of this shift is the DALI-2 (Digital Addressable Lighting Interface) standard.
JINYI is proud to announce the launch of our fully compliant DALI-2 Smart Emergency Lighting Solution. Featuring our independently developed DALI-2 emergency power supplies and a comprehensive range of purpose-built luminaires, this system is designed to make buildings smarter, safer, and more efficient. We will be officially unveiling this complete ecosystem at the upcoming Hong Kong International Lighting Fair this October.

Why the Industry is Shifting Towards Wired DALI Systems
While wireless technologies have made strides, wired DALI systems remain the gold standard for emergency lighting. When lives are on the line, reliability cannot be compromised by signal interference, dead zones, or network dropouts.
-
Universal Standard Protocol: Fully compliant with IEC 62386-202, DALI-2 ensures seamless interoperability. Devices from different manufacturers can communicate flawlessly within the same Building Management System (BMS).
-
Individual Addressability & Precision: Every JINYI DALI-2 device possesses a unique address, allowing facility managers to pinpoint the exact location of a fault down to the specific luminaire.
-
Automated Compliance & Reduced Costs: The system supports automatic Function and Duration testing. Instead of deploying maintenance crews for manual monthly checks, the DALI-2 bus reports real-time battery conditions, lamp status, and test results directly to the control room, drastically reducing operational expenses.
-
Future-Proof Scalability: DALI-2 is inherently flexible, making it the ideal long-term solution for both new constructions and retrofits across commercial, healthcare, and public sectors.
JINYI's Complete DALI-2 Ecosystem
Our R&D team has engineered a robust lineup that provides a plug-and-play experience for global projects. The core of the system includes:
-
Self-Developed DALI-2 Emergency Kits: Available in 2.5W and 5W options, featuring wide voltage outputs (15-100VDC), high-safety LiFePO4 batteries (with a 24-hour charge time), and operating reliably in 0–50°C environments.
-
Purpose-Built Luminaires: A full suite of DALI-2 addressable fixtures, including Bulkheads, Downlights, Twinspots, and Exit Signs, ensuring seamless integration regardless of the architectural requirement.

Expert Selection Guide: How to Configure DALI in Your Projects
A common point of confusion among project managers and lighting designers is deciding between different DALI configurations. Here is the definitive guide to making the right choice for your project:
Scenario A: Standard Emergency Kit + DALI-2 LED Driver
-
How it works: In this setup, the luminaire's normal lighting is controlled by a DALI-2 driver (for dimming, scenes, and daily energy management). However, the emergency backup uses a standard, non-DALI emergency inverter.
-
System capability: The BMS can control the daily light but cannot monitor the emergency battery status or execute central testing. Emergency tests must be done locally (via manual test buttons or local standalone auto-test functions).
-
Best Suited For: Budget-conscious projects, mid-sized offices, or retrofits where the primary goal is daily energy saving (dimming) rather than centralized emergency maintenance.
Scenario B: JINYI DALI-2 Emergency Kit + DALI-2 LED Driver (or Dedicated DALI-2 Emergency Light)
-
How it works: Both the daily lighting control AND the emergency power supply communicate over the DALI-2 Bus. The emergency kit operates as a dedicated "Device Type 1" (Emergency) node.
-
System capability: Full intelligence. The BMS can trigger automated testing, monitor battery health, read real-time fault reports, and maintain digital compliance logs without human intervention.
-
Best Suited For: Hospitals, airports, large-scale commercial complexes, and high-end retail spaces. This is mandatory for projects that require strict legal compliance, central monitoring, and where manual maintenance labor costs are prohibitively high.

Join Us in Hong Kong Ready to upgrade your project specifications? Experience the reliability of JINYI's DALI-2 emergency systems firsthand. Visit our booth at the Hong Kong International Lighting Fair in October to see live demonstrations of our smart topology in action.